80 KW SDMO Diesel Generator 98 KVA, Three phase, Enclosed type, EPA compliant, J80UC3 IV, Brand New, 2 Years Warranty
- JOHN DEERE 4045HFS82, Turbocharged Heavy duty diesel engine, 4 stroke, 1800RPM, Liquid cooled, Electronic governor, U.S. EPA / CARB TIER 3
- LEROY SOMER LSA432L8, 12 Leads brushless alternator. IP23 drip-proof protection, Insulation class H. Electronic Automatic voltage regulation
- SCHNEIDER, Main line circuit breaker, 3 pole, set mounted, wired and maximum output rated for complete generator protection
- SDMO NEXYS, Digital auto-start/stop control panel. All genset parameter, alarms and control functions. CE listed
- SDMO TELYS2, ADVANCED / 06x MULTILINGUAL, Digital auto-start/stop control panel with built-in Remote monitoring/control capability. All genset parameter, alarms and control functions. RS232 and RS485 (OPTIONAL)
- SDMO DAY TANK, Incorporated metallic fuel tank with electronic level sensing, single wall. Daily autonomy: 190L (50Gal) (9 hours runtime autonomy @ 75% load)
EQUIPPED WITH THE FOLLOWING ACCESSORIES AND HIGH PERFORMANCE UPGRADES:
- CN08 ENCLOSURE CUSTOM COLOR UPGRADE: RAL9003 Signal White
BRAND NEW AND FULLY PACKAGED DIESEL GENERATOR SET INCLUDES STANDARD:
- IP56 rated Weather proof / Super Silent enclosure. 12 gauge electro zinc coated steel for maximum corrosion resistance
- AUTO start/stop control feature included for remote start via 2-Wire dry contact
- U.S. EPA / CARB TIER 3 compliant engine as per current U.S. Environmental Protection Agency regulations
- Engine Governor and Regulation: Electronic Isochronous for extremely accurate +/-0.5% speed regulation
- 12 lead reconnectable Alternator, brushless, single bearing, IP23 drip proof protection, Insulation class H/H, AVR R250, +/- 0.5% regulation
- Radiator rated for T°of 50°C [122°F] max with mechanical fan
- Microprocessor based control panel
- 12V charging alternator and 12V electrical starter motor
- 12V charged DC starting battery with electrolyte and cables
- 29dB(A) Critical class silencer installed inside the enclosure
- Dry type Air filter, Fuel filter and Oil filter spin-on elements installed
- Mechanically welded chassis with anti-vibration isolators
- Each unit prototype and individually factory load bank tested prior to shipping in ISO9001:2008 Quality Controlled facilities
- User guide, commissioning and maintenance manual. Wiring diagrams included. (English, Spanish or French)
- The generator accepts 100% rated load in one step as per NFPA110 and meets ISO8528-5 class G-3 for transient response
- Many options available: Aluminum enclosures, UL142 listed fuel tanks, UL1008 automatic transfer switches, Remote annunciators and More
- Compliant with ISO3046, ISO8528, BS4999, BS5514, BS5000PT99, AS1359, IEC34, UTE5100, VDE0530?_?_??and?_?_??ISO9001:2008
IP56 RATED WEATHER PROOF / SUPER SILENT ENCLOSURE FEATURES:
- 12 gauge electro-zinc coated steel for maximum corrosion resistance (Phosphatizing degreasing, Non-chromic passivation, Osmosis purified rinsing and High durability polyester resin thermosetting powder paint)
- 29dB(A) Internal-mounted critical silencer and flexible exhaust connector offering maximum component life and operator safety
- Fade-, scratch-, and corrosion-resistant. Automotive-grade textured finish resulting in advanced corrosion and abrasion protection as well as enhanced edge coverage and color retention
- Up to 51mm (2in) Acoustic insulation with hydrocarbon sealing film that meets UL 94 HF1 / FMVSS 302 flammability classification and repels moisture absorption
- Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design
- Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery
- Cooling air discharge. Weather protective design featuring a vertical air discharge outlet grille. Redirects cooling air up and above enclosure to reduce ambient noise
- Cooling/combustion air intake with a horizontal air inlet. Sized for maximum cooling airflow
- Heavy duty Polyamide plastic hinges, Dichromate galvanized bolting and Stainless steel rivets for lifetime longevity
- 100% modular design, complete enclosure can be removed or installed in under 30 minutes, no disassembly required
- Meets and exceeds NFX41002 Salt spray test, NFT30049 UV Performance test, NFT30038 Paint adhesion test and 2000/14EC Low sound directives
GENERATOR POWER RATINGS, VOLTAGES, DIMENSIONS AND WEIGHT:
- STANDARD POWER RATINGS @ 208/120V: 74KW (93KVA) STANDBY, 67KW (84KVA) PRIME, 60HZ, 3PHASE, 0.8PF, 1800RPM
- STANDARD POWER RATINGS @ 220/127V: 78KW (98KVA) STANDBY, 71KW (89KVA) PRIME, 60HZ, 3PHASE, 0.8PF, 1800RPM
- STANDARD POWER RATINGS: 80KW (100KVA) STANDBY, 73KW (91KVA) PRIME, 60HZ, 3PHASE, 0.8PF, 1800RPM, 480/277V
- STANDARD AVAILABLE VOLTAGES: 208/120V, 220/110V, 220/127V, 240/120V, 240/139V, 416/240V, 440/254V, 460/265V OR 480/277V
- DIMENSIONS ENCLOSED SUPER SILENT TYPE:: 2554mm [101in] X 1150mm [45in] X 1680mm [66in], 1590kg [3505lbs] Net
J80UC3 IV - SDMO | 80 kW 98 kVA
Return & Cancellation Policy
-
Order Cancellations: Orders cancelled after placement are subject to a 5% administrative fee.
-
Returns: Returns are accepted within 30 days of shipment only if the unit is unused and has never had fuel or oil added.
-
Fees: A 25% restocking fee applies to all authorized returns. Original and return shipping charges are non-refundable.
-
Inspection: Damage during transit must be noted on the Bill of Lading (BOL) at the time of delivery to be eligible for an insurance claim.
-
Government Contracts: For Prime Contractors and Federal Agencies, we honor all negotiated FAR/DFARS flow-down provisions as specified in the formal Purchase Order (PO).
-
quipment Storage Requirements: Proper on-site storage is critical to maintaining the integrity of the alternator and electrical components.
-
Moisture Protection: If the generator is stored on-site prior to installation, it must be kept in a dry, covered, and well-ventilated environment.
-
Anti-Condensation Heaters: For units equipped with internal anti-condensation (space) heaters, the Buyer is responsible for providing a temporary 120V/240V power source to these heaters immediately upon delivery.
-
Validation: Heaters must remain energized during the entire storage period to keep the alternator windings above the dew point and prevent moisture absorption.
-
Liability: Failure to maintain the heaters or provide adequate dry storage may void the manufacturer’s warranty regarding insulation resistance (IR) and winding failure. We recommend performing an insulation test (Megger test) prior to the first start-up if the unit has been stored for more than 30 days.
-