top of page

80 KW Trailer Generator, John Deere TPEM EPA Tier 3 Flex

100 kVA John Deere generator for trailer and mobile power

GPR-J80-60T3F-2SA

BRAND NEW, 12GA MARINE-GRADE ALUMINUM SUPER SILENT ENCLOSURE 

100% DESIGNED, ENGINEERED, ASSEMBLED AND TESTED IN USA 

Available in both trailer and non-trailer versions based upon application requirements and customer needs 

80 KW GENERATOR POWER RATINGS: 

>3PHASE 480/277V: 80KW (100KVA) 120A STANDBY, 75KW (94KVA) 113A PRIME, 0.8PF, 60HZ 

>3PHASE 208/120V: 80KW (100KVA) 278A STANDBY, 74KW (93KVA) 257A PRIME, 0.8PF, 60HZ 

>1PHASE 240/120V: 80KW (80KVA) 333A STANDBY, 73KW (73KVA) 304A PRIME, 1.0 PF, 60HZ 

POWERED BY PREMIUM HEAVY DUTY INDUSTRIAL COMPONENTS FOR MAXIMUM DURABILITY, EXCELLENT RELIABILITY AND WORLDWIDE SUPPORT:

>DIESEL ENGINE: JOHN DEERE 4045HF285-3126, Turbocharged, heavy duty diesel engine, 1800rpm, Liquid cooled, Electronic governor, U.S. EPA / TIER 3 FLEX compliant 

>EMISSIONS COMPLIANCE: U.S. EPA / TPEM TIER 3 FLEX (Flexibility Provisions compliant engine) as per current U.S. Environmental Protection Agency regulations (TPEM 40 CFR Part §1039.625)

>AC ALTERNATOR: LEROY SOMER TAL-044-H, 12 Leads brushless alternator. IP23 drip-proof protection, Insulation class H. Electronic Automatic voltage regulation 

>ALTERNATOR EXCITATION: LEROY SOMER AREP, PMG-grade auxiliary excitation and AVR upgrade for 270% (270IN:5s) short-circuit reactance capability 

>ADVANCED DIGITAL CONTROLLER: DEEPSEA DSE7320 MKII digital auto-start/stop control panel. All genset parameter, alarms and control functions. RS232 and RS485. UL LISTED 

>CIRCUIT BREAKER: ABB 400AMP, Manual Main line circuit breaker, 3 poles, set mounted, wired and maximum output rated for complete generator protection 

>DIGITAL VOLTAGE REGULATION: DEEPSEA DSEA109 Advanced Digital Voltage Regulator upgrade with optional motor soft-start ramp up capability

CORROSION-PROOF MARINE GRADE ALUMINUM ENCLOSURE FOR LIFETIME LONGEVITY AND EXCELLENT SOUND PERFORMANCE:

>35DBA CRITICAL SILENCER: MIRATECH COWL TXS, CRITICAL class spiral silencer for 28 to 35dBA sound reduction. Aluminized steel construction 

>ENCLOSURE CONSTRUCTION: AL5052, 12GA, Marine-Grade ALUMINUM alloy panels enclosure construction with stainless steel hardware 

>ENCLOSURE TYPE: IP56 rated Weather proof, sound attenuated enclosure. 12-gauge aluminum for maximum corrosion resistance 

>SOUND ATTENUATING MATERIAL: Up to 50 mm (2 in) of Polydamp® Acoustical Foam with Tuffylm® urethane lining, designed to give maximum sound absorption. The foam comes with 1.85 density (lb/ft3). Flame resistant to UL94-HF1 standard.  

80 KW TRAILER GENERATOR FEATURES FOR COMPLETE MOBILITY, TOTAL VERSATILITY AND MAXIMUM ROI:

>TRUE DOUBLE-WALLED FUEL TANK: 175Gal (662L), double walled, integral metallic fuel tank with electronic fuel level sender for control panel readings, alarms and shutdowns. TRUE Double-walled construction with 110% containment capability and leak detection switch 

>RUNTIME AUTONOMY (DIESEL): 35 Hours @ 75% load, 29 Hours @ 100% load 

>ENVIRONMENTAL CONTAINMENT: 110% rated containment of oil, coolant and fuel. Segmented containment design allows for separate containment of oil-coolant, fuel and water 

>VOLTAGE SELECTOR SWITCH: SALZER 3-position manual voltage selector switch for effortless switching between 1PHASE-240/120V, 3PHASE 208/120V and 3PHASE 480/277V connections 

>POWER DISTRIBUTION PANEL: Enclosure-surface mounted, rental-type, full distribution panel includes: 2x 20AMP GFCI duplex receptacles, 3x 50AMP twist lock receptacles, 1x FULL SET color coded camlocks, 1x FULL SET bus bars with 500mcm mechanical lugs 

>EXTERNAL SHORE POWER CONNECTOR: Externally mounted quick-connector provide convenient access to power the battery charger and coolant heater 

>EXTERNAL COMMUNICATION CONNECTORS: 1x set of remote start/stop terminals and 1x surface mounted USB-B type connector for effortless control software configuration

>EXTERNAL FUEL FILL: Externally mounted lockable fuel fill installed on the enclosure 

>EXTERNAL CONNECTION PORTS: 4x externally mounted quick access ports installed on the enclosure for coolant drain; oil drain; fuel supply; and fuel return 

>DOUBLE CRITICAL-ACCESS EMERGENCY STOP BUTTONS: 1x externally mounted recessed emergency-stop button installed on the enclosure and 1x internally mounted button next the control cabinet 

>BATTERY DISCONNECT SWITCH: Manually operated battery quick disconnect switch  

>LED LIGHTING: 300 lumens, 0.3A, 12VDC, waterproof white LED strip in aluminum housing installed in the mechanical lugs compartment 

>SHUNT TRIP: 12VDC shunt trip

>SYSTEM-WIDE DIFFERENTIAL PROTECTION ON ALL OUTPUTS: LOVATO 31RM48 Type A earth leakage relay with 1 operation threshold, configurable automatic or manual resetting and LED indicators 

>ACCIDENTAL SWITCHOVER PROTECTION: Automatic breaker shunt-trip in the case of accidental operation of the voltage selector switch while the engine is running

80 KW Trailer Generator, 100 KVA John Deere Tier 3 FLEX

$0.00Price
Excluding Sales Tax
Quantity
  • Return & Cancellation Policy

    • Order Cancellations: Orders cancelled after placement are subject to a 5% administrative fee.

       

    • Returns: Returns are accepted within 30 days of shipment only if the unit is unused and has never had fuel or oil added.

    • Fees: A 25% restocking fee applies to all authorized returns. Original and return shipping charges are non-refundable.

    • Inspection: Damage during transit must be noted on the Bill of Lading (BOL) at the time of delivery to be eligible for an insurance claim.

    • Government Contracts: For Prime Contractors and Federal Agencies, we honor all negotiated FAR/DFARS flow-down provisions as specified in the formal Purchase Order (PO).

  •  Equipment Storage Requirements: Proper on-site storage is critical to maintaining the integrity of the alternator and electrical components.

    • Moisture Protection: If the generator is stored on-site prior to installation, it must be kept in a dry, covered, and well-ventilated environment.

    • Anti-Condensation Heaters: For units equipped with internal anti-condensation (space) heaters, the Buyer is responsible for providing a temporary 120V/240V power source to these heaters immediately upon delivery.

    • Validation: Heaters must remain energized during the entire storage period to keep the alternator windings above the dew point and prevent moisture absorption.

    • Liability: Failure to maintain the heaters or provide adequate dry storage may void the manufacturer’s warranty regarding insulation resistance (IR) and winding failure. We recommend performing an insulation test (Megger test) prior to the first start-up if the unit has been stored for more than 30 days.

bottom of page